Output Signal | Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc Optional 3-wire: 0-10 V / Vs = 14-30 Vdc Optional 3-wire ratiometric: Vsig = 0.5-4.5 Vs / Vs = 5 ± 0.5 Vdc |
| |
Accuracy | ±0.5% FSO |
| |
Permissible Load | 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm 3-wire: Rmin = 10 kOhm |
| |
Influence Effects | Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| |
Response Time | 2-wire: <10 msec 3-wire: <3 msec |
| |
Measuring Rate
| 1 kHz
|
| |
Thermal Error
| <±0.3% FSO / 10Km, Compensated range 0..70°C
|
| |
Permissible Temperatures
| Medium: -40°F to 257°F (-40°C to 125°C) Electronics environment: -40°F to 185°F (-40°C to 85°C) Storage: -40°F to 185°F (-40°C to 85°C)
|
| |
Short-circuit Protection
| Permanent 3-wire ratiometric: None |
| |
Reverse Polarity Protection
| No damage. No function.
|
| |
Electromagnetic Protection
| Emission and immunity according to EN 61326
|
| |
Stability
| Vibration: 20 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6 Shock: 500 g / 1 msec according to DIN EN 60068-2-27
|
| |
Pollution Degree
| 4, electrical equipment for outdoor use
|
| |
Pressure Port / Housing
| 316Ti Stainless steel/304 Stainless steel
|
| |
Diaphragm
| 17-4PH Stainless steel, welded |
| |
Weight
| 120 g
|
| |
Current Consumption
| 2-wire: 25 mA max 3-wire ratiometric: 3 mA 3-wire voltage: 5 mA (short-circuit current 20 mA)
|
| |
Long-term Stability
| <±0.3% FSO/yr at reference conditions
|
| |
Operation Life
| >100 × 106 cycles
|
| |
CE Conformity