Output Signal | Standard 2-wire: 4-20 mA / Vs = 12-36 Vdc Ex-protection: Vs = 14-28 Vdc Optional 3-wire: 0-20 mA / Vs = 14-36 Vdc 0-10 V / Vs = 14-36 Vdc |
| |
Accuracy
| ±0.25% FSO
|
| |
Permissible Load
| Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm
|
| |
Influence Effects
| Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm
|
| |
Response Time
| <10 msec
|
| |
Thermal Error
| <±0.2% FSO / 10K In compensated range: -13°F to 185°F (-25°C to 85°C)
|
| |
Permissible Temperatures
| Medium: -13°F to 275°F (-25°C to 135°C) Electronics environment: -13°F to 185°F (-25°C to 85°C) Ex-protection Zone 0: -4°F to 140°F (-20°C to 60°C) Ex-protection Zone 1/higher: -13°F to 158°F (-25°C to 70°C) Storage: -40°F to 212°F (-40°C to 100°C)
|
| |
Short-circuit Protection
| Permanent
|
| |
Reverse Polarity Protection
| No damage. No function.
|
| |
Electromagnetic Protection
| Emission and immunity according to EN 61326
|
| |
Ex-protection
| SS pressure port: Zone 0: II 1 G Ex ia IIC T4 Zone 20: II 1 D Ex tD A20 IP65 T 85°C Safety technical max values: Vi = 28 V, I = 93 mA, Pi = 660 mW, Ci < 1nF, L < 10 µH
|
| |
Stability
| Vibration: 10 g RMS (20 to 2,000 Hz) Shock: 100 g / 11 msec
|
| |
Pollution Degree
| 4, electrical equipment for outdoor use
|
| |
Housing | 304 SS |
| |
Pressure Port
| 316 Ti SS
|
| |
Wetted Parts
| Seals: PN < 1450 psi: FKM (Viton®, Kalrez®). PN > 1450 psi: NBR (Buna N). Others available. Diaphragm: Ceramic AI2O3 96%
|
| |
Weight
| 140 g
|
| |
Current Consumption | Current: 25 mA max Voltage: 7 mA max
|
| |
SIL 2
| IEC 61508 / IEC 61511 |
| |
Operation Life
| >100 × 106 cycles
|
| |
Connecting Cables
| Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |