ENERGY EFFICIENT LOW VOLTAGE DISTRIBUTION TRANSFORMERS

HPS offers three lines of energy efficient low voltage distribution transformers which meet or exceed U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies. For more information on CSA C802.2 minimum efficiency values for dry-type transformers please click here.

Energy Efficient General Purpose Transformers

Energy efficient general purpose low voltage distribution transformers are rated for 600 volts and below. They are generally used for supplying appliance, lighting, heating, motorized machine and power loads from electrical distribution systems. For non-linear loads, all standard energy efficient distribution transformers have to be derated to allow for additional heat due to harmonic losses.

Energy Efficient K-Factor Transformers

Energy efficient k-factor low voltage distribution transformers are rated for 600 volts and below. The use of k-factor distribution transformers has become a popular means of addressing harmonic related overheating problems where electronic ballasts, drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations. These non-linear loads generate harmonic currents which can substantially increase transformer losses. The k-rated transformer has a more rugged design intended to prevent failure due to overheating.

Energy Efficient Harmonic Mitigating Transformers

Energy efficient harmonic mitigating low voltage distribution transformers are rated for 600 volts and below. Harmonic mitigating transformers are superior to k-rated and general purpose transformers in that they reduce voltage distortion (flat-topping) and power losses due to current harmonics created by single-phase, non-linear loads such as computer equipment. Secondary windings are arranged to cancel zero sequence fluxes and eliminate primary winding circulation currents. They treat zero sequence harmonics (3rd, 9th and 15th) within the secondary winding and 5th and 7th harmonics upstream with appropriate phase shifting.

Energy Efficient General Purpose Transformers

HPS Sentinel ® Series

HPS Sentinel® general purpose distribution transformers are rated for 600 volts and below. They are generally used for supplying appliance, lighting, heating, motorized machine and power loads from electrical distribution systems. For non-linear loads, all standard energy efficient distribution transformers have to be derated to allow for additional heat due to harmonic losses.

HPS provides two lines of energy efficient general purpose distribution transformers:

HPS Sentinel®

  • Meets U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at 35% of rated load
  • Efficiencies are calculated under a linear load profile
  • 60 Hz frequency
  • Ratings from 15 to 333 kVA single phase and 15 to 1500kVA three phase
  • 6 standard single phase voltage groups and 10 standard three phase voltage groups available
  • Copper and aluminum available
  • UL listed
  • CSA certified
  • 10 year warranty
  • Custom sizes, ratings and styles available upon request

HPS SuperSentinel®

  • Exceeds U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at an operating range at 35% of rated load
  • Efficiency performance will meet the NEMA Premium® guidelines; 30% lower losses than U.S. DOE 10 CFR Part 431 (and/or TP1) and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards when measured under a linear load profile
  • 60 Hz frequency
  • Ratings from 15 to 333 kVA single phase and 15 to 1500kVA three phase
  • 6 standard single phase voltage groups and 10 standard three phase voltage groups available
  • Copper and aluminum available
  • UL listed
  • CSA certified
  • 10 year warranty
  • Custom sizes, ratings and styles available upon request


As a Partner in the NEMA Premium® Transformer Program, Hammond Power Solutions has determined that this product meets the NEMA Premium® Efficiency specifications for premium energy efficiency.

NEMA Premium® is a trademark of National Electrical Manufacturers Association

Energy Efficient K-Factor Transformers

HPS Synergy® Series

PS Synergy® energy efficient k-factor distribution tranformers are rated for 600 volts and below. K-factor transformers are most frequently used for applications such as commercial or institutional buildings, will, by definition, they supply widely varied single phase loads. Energy Efficient K-Factor transformers are energy efficient general purpose transformers, but are designed to tolerate the harmonics distortion associated with non-linear loads.

HPS provides two lines of energy efficient k-factor transformers:

HPS Synergy®

Energy efficient k-factor transformers are designed to tolerate heating due to harmonics associated with non-linear loads. Harmonics can indicate their presence in a number of ways: overheating, device malfunctions, telephone interference, equipment vibration, and breakers tripping.

  • Meets U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at 35% of rated load
  • Efficiencies are calculated under a linear load profile
  • 60 Hz frequency
  • Three phase ratings from 15 to 1500kVA three phase
  • 2 standard three phase voltage groups available at k-factor ratings of K4, K13 and K20
  • Copper and aluminum available
  • UL listed
  • CSA certified
  • 10 year warranty
  • Custom sizes, ratings and styles available upon request
  • HPS SuperSynergy®

    The HPS SuperSynergy® energy efficient k-factor transformer exceeds DOE 10 CFR Part 431 and (if applicable) CSA C802.2 efficiencies over a range of linear loads. It will not only satisfy the necessity for running at k-factor modern building load types, but in addition, because of the increasing need for energy conservation, they are much more efficient than that of our standard energy efficient line.

    • Efficiency performance will meet the NEMA Premium® guidelines; 30% lower losses than U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards when measured under a linear load profile at 35% of rated load.
    • Efficiency will meet or exceed U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards for linear load even at 50% of rated load when measured under a non-linear load up to K13.
    • 60 Hz frequency
    • Three phase ratings from 15 to 150 kVA
    • 2 standard three phase voltage groups available at k-factor ratings of K4, K13 and K20
    • Copper and aluminum available
    • UL listed
    • CSA certified
    • 10 year warranty
    • Custom sizes, ratings and styles available upon request


    As a Partner in the NEMA Premium® Transformer Program, Hammond Power Solutions has determined that this product meets the NEMA Premium® Efficiency specifications for premium energy efficiency.

    NEMA Premium® is a trademark of National Electrical Manufacturers Association.

    Energy Efficient Harmonic Mitigating Transformers

    HPS Centurion® Series

    PS Centurion® Energy Efficient Harmonic Mitigating distribution tranformers are rated for 600 volts and below. Energy efficient harmonic mitigating transformers with zero sequence flux cancellation technology, is specifically designed to treat the harmonics generated by computer equipment and other non-linear, power electronic loads.

    Superior to K-rated and conventional transformers in reducing voltage distortion (flat-topping) and power losses due to current harmonics created by single-phase, non-linear loads such as computer equipment.

    HPS provides two lines of energy efficient harmonic mitigating transformers:

    HPS Centurion®

    The HPS Centurion® energy efficient, harmonic mitigating transformer with zero sequence flux cancellation technology is specifically designed to treat the harmonics generated by computer equipment and other non-linear, power electronic loads. Combining zero sequence flux cancellation with phase shifting treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th, harmonics within its secondary windings.

    Typical applications of severe non-linear loading conditions include data centers, internet-service providers, telecom sites, call centers, broadcast centers, etc.

    • Meets U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at an operating range from 35% to 65% of rated load.
    • Meets U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards when measured under a non-linear load profile up to K20 in an operating range from 35% to 50%.
    • 60 Hz frequency
    • Three phase ratings from 15 to 1500 kVA
    • 6 standard three phase voltage groups available
    • Copper & aluminum available
    • UL listed
    • CSA certified
    • 10 year warranty
    • Custom sizes, ratings and styles available upon request

    HPS SuperCenturion®

    • Exceeds U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiencies at 35% of rated load.
    • Efficiency performance will meet NEMA Premium® guidelines; 30% lower losses than U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards when measured under a linear load profile.
    • Efficiencies will exceed U.S. DOE 10 CFR Part 431 (and/or TP1) efficiency standards and the Canadian Energy Efficiency Regulations SOR/94-651 (and/or C802.2) efficiency standards at an operating range from 35% to 65% of rated load when measured under a non-linear load profile up to K20.
    • 60 Hz frequency
    • Three phase ratings from 15 to 1500 kVA
    • 6 standard three phase voltage groups available
    • Copper & aluminum available
    • UL listed
    • CSA certified
    • 10 year warranty
    • Custom sizes, ratings and styles available upon request

    As a Partner in the NEMA Premium® Transformer Program, Hammond Power Solutions has determined that this product meets the NEMA Premium® Efficiency specifications for premium energy efficiency.

    NEMA Premium® is a trademark of National Electrical Manufacturers Association.

    Sort By:
    1 2 3 ... 66
    Hammond Power Solutions H1EM015BB00
    Hammond Power Solutions H1EM015BB00

    HMT 3PH 15kVA 208-208 CU more info
    Hammond Power Solutions H1EM015BB00S
    Hammond Power Solutions H1EM015BB00S

    H1EM015BB00S more info
    Hammond Power Solutions H1EM015BB30
    Hammond Power Solutions H1EM015BB30

    HMT 3PH 15kVA 208-208 CU more info
    Hammond Power Solutions H1EM015BB30S
    Hammond Power Solutions H1EM015BB30S

    HMT 3PH 15kVA 208-208 AL more info
    Hammond Power Solutions H1EM015BK00
    Hammond Power Solutions H1EM015BK00

    HMT 3PH 15kVA 208-480 CU more info
    Hammond Power Solutions H1EM015BK00S
    Hammond Power Solutions H1EM015BK00S

    H1EM015BK00S more info
    Hammond Power Solutions H1EM015BK30
    Hammond Power Solutions H1EM015BK30

    H1EM015BK30 more info
    Hammond Power Solutions H1EM015BK30S
    Hammond Power Solutions H1EM015BK30S

    H1EM015BK30S more info
    Hammond Power Solutions H1EM015KB00
    Hammond Power Solutions H1EM015KB00

    H1EM015KB00 more info
    Hammond Power Solutions H1EM015KB00S
    Hammond Power Solutions H1EM015KB00S

    HMT 3PH 15kVA 480-208 AL more info
    Hammond Power Solutions H1EM015KB30
    Hammond Power Solutions H1EM015KB30

    H1EM015KB30 more info
    Hammond Power Solutions H1EM015KB30S
    Hammond Power Solutions H1EM015KB30S

    H1EM015KB30S more info
    Hammond Power Solutions H1EM015KK00
    Hammond Power Solutions H1EM015KK00

    HMT 3PH 15kVA 480-480 CU more info
    Hammond Power Solutions H1EM015KK00S
    Hammond Power Solutions H1EM015KK00S

    H1EM015KK00S more info
    Hammond Power Solutions H1EM015KK30
    Hammond Power Solutions H1EM015KK30

    HMT 3PH 15kVA 480-480 CU more info
    Hammond Power Solutions H1EM015KK30S
    Hammond Power Solutions H1EM015KK30S

    H1EM015KK30S more info
    Hammond Power Solutions H1EM015PB00
    Hammond Power Solutions H1EM015PB00

    HMT 3PH 15kVA 600-208 CU more info
    Hammond Power Solutions H1EM015PB00S
    Hammond Power Solutions H1EM015PB00S

    H1EM015PB00S more info
    Hammond Power Solutions H1EM015PB30
    Hammond Power Solutions H1EM015PB30

    H1EM015PB30 more info
    Hammond Power Solutions H1EM015PB30S
    Hammond Power Solutions H1EM015PB30S

    H1EM015PB30S more info
       
     
    1 2 3 ... 66